A dedicated range of Top Flange I-joist hangers meeting the unique needs of I-joists while offering superior performance and ease of installation.

ITS
The innovative ITS sets a new standard for engineered wood top flange hangers. The ITS installs faster and uses fewer nails than any other EWP top flange hanger. The new Strong-Grip™ seat and Funnel Flange™ features allow standard joist installation without requiring joist nails resulting in the lowest installed cost. The Strong-Grip seat firmly secures I-joists with flange thicknesses from 1 1/8" to 1 1/2".

MIT/HIT - Patented Positive Angle Nailing (PAN)
PAN is specifically designed for I-joists when used with the MIT or HIT. With PAN, the nail hole material is not removed, but is formed to channel and confine the path of the nail at approximately 45°. PAN minimizes splitting of the flanges while permitting time-saving nailing from a better angle.

See Top Flange Hanger tables.

Refer to Joist Manufacturer's literature or appropriate Simpson Strong-Tie Connector Selection Guide for actual joist sizes.

Material: ITS—18 gauge; MIT, HIT—16 gauge

Finish: Galvanized

Installation:

Allowable Loads: Options:

top Gallery:
  roll over images below to see larger image
 
ITS The Strong-Grip™ seat secures I-joists in position without joist nails Typical ITS Installed on LVL MIT
 
Typical MIT Installed on a Double LVL HIT HIT Installation
on a 3x Nailer mounted on a Steel Beam
 


top ITS Installation Sequence
  roll over images below to see larger image
 
Step 1
Attach the ITS to the header
Step 2
Slide the I-joist downward into the ITS until it rests above the Strong-Grip™ seat.
Step 3
Firmly push or snap I-joist fully into the seat of the ITS.

top Positive Angle Nailing
  roll over images below to see larger image
 
Correct Nailing Approx. 45° angle Nail too long Nail at wrong angle
Toe-Nailing
Toe nailing causes squeaks and improper hanger installations. Do not toe nail I-joists before installing top flange or face mount hangers.

top Wood I-Joists:
  roll over images below to see larger image
 
I-JOIST AS A HEADER INSTALLATIONS
 
  Face Mount Hanger Top Flange Hanger
 
 
When face mount hangers are attached to I-joist headers, backer blocks must be installed to provide a nailing surface for the hanger nails. The backer blocks should be installed on both sides of the web and attached together with a minimum of 10-10d nails. The hanger nails should extend through the web. Contact the I-Joist manufacture for additional design considerations.
When top flange hangers are attached to I-joist headers, a backer block must be installed to prevent the top flange from rotating under load. The backer blocks should be installed with a minimum of 10-10d nails clinched. Check with the joist manufacturer for additional design considerations.
   
 
top IT Series With Various Header Applications:See code report listings below
Table
  1. Uplift loads are based on DF/SP lumber and have been increased for wind or earthquake loading with no further increase allowed. Reduce where other loads govern. For SPF/HF use 0.86 x DF/SP uplift load.
  2. ITS uplift loads are valid for all lumber species and need not be reduced for duration of load.
  3. Applies to LVL headers made primarily from Douglas Fir or Southern Pine. For LVL made primarily from Spruce Pine Fir or similar less dense veneers, use the values found in the SPF/HF column.
  4. DF I-joists include flanges made from solid sawn Douglas Fir, LVL made primarily of Douglas Fir/Southern Pine, or LSL. For flanges with thicknesses from 1 5/16 to 1 3/8, use 0.85 of the I-joist header load. For flanges with thicknesses from 1 1/8 to 1 1/4, use 0.75 of the I-joist header load.
  5. SCL (structural composite lumber) is LVL, LSL, and Parallam® PSL.
  6. Web stiffeners required for the ITS Alternate Installation when installing optional joist nails for additional uplift load.
  7. Code Values are based on DF/SP header species.
  8. I-joists with flanges less than 1 5/16" thick used in combination with hangers thinner than 14 gauge may deflect an additional 1/32" beyond the standard 1/8" limit.
  9. For 2 1/2" and 2 7/16" wide joists, see top flange hanger tables for allowable loads.

Parallam® is a registered trademark of iLevel by Weyerhaeuser.

top Nailer Table:

This table indicates various allowable loads for ITS/MIT/HIT hangers used on wood nailers. The header nail type must be substituted for those listed in other tables. See technical bulletin T-NAILERUPLFT for other uplift values and options.

NAILS: 16d = 0.162" dia. x 3 1/2" long, 16dx2 1/2= 0.162" dia.x 2 1/2" long, 10d = 0.148" dia. x 3" long, 10dx1 1/2 = 0.148" dia. x 1 1/2" long.
See other nail sizes and information.
Table
  1. Uplift loads are based on DF/SP members only. See T-NAILERUPLFT for SPF/HF values.
top Optional Nailing For Increased Uplift:
Table
  1. Loads are based on Doug Fir, and have been increased for wind or earthquake loading with no further increase allowed. Reduce where other loads govern.
  2. Web stiffeners are required on I-joist for additional nailing.
next  top Code Reports (PDFs):
Legacy Reports
  IAPMO ES ER ICC-ES ESR CITY OF LOS ANGELES STATE OF FLORIDA ICC-ES NER ICC-ES ER ICC-ES ES
HITSee specific model numbers for code listings.
HIT318  ESR-2615 / ESR-2523 * RR25803 FL10667      
HIT320  ESR-2615 / ESR-2523 * RR25803 FL10667      
HIT322  ESR-2615 / ESR-2523 * RR25803 FL10667      
HIT324  ESR-2615 / ESR-2523 * RR25803 FL10667      
HIT326  ESR-2615 / ESR-2523 * RR25803 FL10667      
HIT3518  ESR-2615 / ESR-2523 * RR25803 FL10667      
HIT3520  ESR-2615 / ESR-2523 * RR25803 FL10667      
HIT418  ESR-2615 / ESR-2523 * RR25803 FL10667      
HIT420  ESR-2615 / ESR-2523 * RR25803 FL10667      
HIT422  ESR-2615 / ESR-2523 * RR25803 FL10667      
HIT424  ESR-2615 / ESR-2523 * RR25803 FL10667      
HIT426  ESR-2615 / ESR-2523 * RR25803 FL10667      
ITSSee specific model numbers for code listings.
ITS1.56/11.88  ESR-2615 / ESR-2523 * RR25803 FL10667      
ITS1.56/9.25 No code listing. Please contact us for test data.
ITS1.56/9.5  ESR-2615 / ESR-2523 * RR25803 FL10667      
ITS1.81/11.88  ESR-2615 / ESR-2523 * RR25803 FL10667      
ITS1.81/14  ESR-2615 / ESR-2523 * RR25803 FL10667      
ITS1.81/16  ESR-2615 / ESR-2523 * RR25803 FL10667      
ITS1.81/9.5  ESR-2615 / ESR-2523 * RR25803 FL10667      
ITS2.06/11.88  ESR-2615 / ESR-2523 * RR25803 FL10667      
ITS2.06/14  ESR-2615 / ESR-2523 * RR25803 FL10667      
ITS2.06/16  ESR-2615 / ESR-2523 * RR25803 FL10667      
ITS2.06/9.5  ESR-2615 / ESR-2523 * RR25803 FL10667      
ITS2.37/11.88  ESR-2615 / ESR-2523 * RR25803 FL10667      
ITS2.37/14  ESR-2615 / ESR-2523 * RR25803 FL10667      
ITS2.37/16  ESR-2615 / ESR-2523 * RR25803 FL10667      
ITS2.37/9.5  ESR-2615 / ESR-2523 * RR25803 FL10667      
ITS2.56/11.25  ESR-2615 / ESR-2523 * RR25803 FL10667      
ITS2.56/11.88  ESR-2615 / ESR-2523 * RR25803 FL10667      
ITS2.56/13  ESR-2615 / ESR-2523 * RR25803 FL10667      
ITS2.56/14  ESR-2615 / ESR-2523 * RR25803 FL10667      
ITS2.56/16  ESR-2615 / ESR-2523 * RR25803 FL10667      
ITS2.56/9.37  ESR-2615 / ESR-2523 * RR25803 FL10667      
ITS2.56/9.5  ESR-2615 / ESR-2523 * RR25803 FL10667      
ITS3.56/11.25  ESR-2615 / ESR-2523 * RR25803 FL10667      
ITS3.56/11.88  ESR-2615 / ESR-2523 * RR25803 FL10667      
ITS3.56/13  ESR-2615 / ESR-2523 * RR25803 FL10667      
ITS3.56/14  ESR-2615 / ESR-2523 * RR25803 FL10667      
ITS3.56/16  ESR-2615 / ESR-2523 * RR25803 FL10667      
ITS3.56/9.25  ESR-2615 / ESR-2523 * RR25803 FL10667      
ITS3.56/9.37  ESR-2615 / ESR-2523 * RR25803 FL10667      
ITS3.56/9.5    RR25803 FL10667      
MITSee specific model numbers for code listings.
MIT1.81/14  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT1.81/16  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT11.88  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT211.88  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT211.88-2  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT29.5  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT29.5-2  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT311.88  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT311.88-2  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT314  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT314-2  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT316  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT318  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT320  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT3511.88  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT3511.88-2  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT3514  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT3514-2  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT3516  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT3518  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT3520  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT359.5-2  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT39.5-2  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT4.12/11.88  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT4.12/14  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT4.12/9.5  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT4.28/11.88  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT4.28/14  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT4.28/9.5  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT4.75/16  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT411.88  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT414  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT416  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT418  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT420  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT49.5  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT5.12/16  ESR-2615 / ESR-2523 * RR25803 FL10667      
MIT9.5  ESR-2615 / ESR-2523 * RR25803 FL10667      

* ESR-2523 is an Index of many of Simpson Strong-Tie Stamped and Welded Cold-formed Steel Products for Wood or Cold-formed Steel Construction



next  topDrawings: To download drawings, right-click or Ctrl-click on the link, then choose "Save Target As..."
Download the Simpson Strong-Tie® AutoCAD® Menu, which allows you to insert Ortho views directly into your AutoCAD drawing.

 ORTHOGRAPHIC
PERSPECTIVE
HITNone for this model None for this model
HIT318None for this model None for this model
HIT320None for this model None for this model
HIT322 HIT322: DWG | DXF
HIT322 front view: DWG | DXF
HIT322 left view: DWG | DXF
HIT322 right view: DWG | DXF
HIT322 top view: DWG | DXF
None for this model
HIT324None for this model None for this model
HIT326None for this model None for this model
HIT3518None for this model None for this model
HIT3520None for this model None for this model
HIT418None for this model None for this model
HIT420None for this model None for this model
HIT422 HIT422: DWG | DXF
HIT422 front view: DWG | DXF
HIT422 left view: DWG | DXF
HIT422 right view: DWG | DXF
HIT422 top view: DWG | DXF
None for this model
HIT424 HIT424: DWG | DXF
HIT424 front view: DWG | DXF
HIT424 left view: DWG | DXF
HIT424 right view: DWG | DXF
HIT424 top view: DWG | DXF
None for this model
HIT426None for this model None for this model
ITS ITS series: DWG | DXF
ITS series front view: DWG | DXF
ITS series right view: DWG | DXF
ITS series top vew: DWG | DXF
None for this model
ITS1.56/11.88None for this model None for this model
ITS1.56/9.25None for this model None for this model
ITS1.56/9.5None for this model None for this model
ITS1.81/11.88None for this model None for this model
ITS1.81/14None for this model None for this model
ITS1.81/16None for this model None for this model
ITS1.81/9.5None for this model None for this model
ITS2.06/11.88None for this model None for this model
ITS2.06/14None for this model None for this model
ITS2.06/16None for this model None for this model
ITS2.06/9.5None for this model None for this model
ITS2.37/11.88None for this model None for this model
ITS2.37/14None for this model None for this model
ITS2.37/16None for this model None for this model
ITS2.37/9.5None for this model None for this model
ITS2.56/11.25None for this model None for this model
ITS2.56/11.88None for this model None for this model
ITS2.56/13None for this model None for this model
ITS2.56/14None for this model None for this model
ITS2.56/16None for this model None for this model
ITS2.56/9.37None for this model None for this model
ITS2.56/9.5None for this model None for this model
ITS3.56/11.25None for this model None for this model
ITS3.56/11.88None for this model None for this model
ITS3.56/13None for this model None for this model
ITS3.56/14None for this model None for this model
ITS3.56/16None for this model None for this model
ITS3.56/9.25None for this model None for this model
ITS3.56/9.37None for this model None for this model
ITS3.56/9.5None for this model None for this model
MIT MIT series: DWG | DXF
MIT series front view: DWG | DXF
MIT series left view: DWG | DXF
MIT series right view: DWG | DXF
MIT series top view: DWG | DXF
MIT: DWG | DXF
MIT Double LVL Installation: DWG | DXF
MIT1.81/14None for this model None for this model
MIT1.81/16None for this model None for this model
MIT11.88None for this model None for this model
MIT211.88None for this model None for this model
MIT211.88-2None for this model None for this model
MIT29.5None for this model None for this model
MIT29.5-2None for this model None for this model
MIT311.88None for this model None for this model
MIT311.88-2None for this model None for this model
MIT314None for this model None for this model
MIT314-2None for this model None for this model
MIT316None for this model None for this model
MIT318None for this model None for this model
MIT320None for this model None for this model
MIT3511.88None for this model None for this model
MIT3511.88-2None for this model None for this model
MIT3514None for this model None for this model
MIT3514-2None for this model None for this model
MIT3516None for this model None for this model
MIT3518None for this model None for this model
MIT3520None for this model None for this model
MIT359.5-2None for this model None for this model
MIT39.5-2None for this model None for this model
MIT4.12/11.88None for this model None for this model
MIT4.12/14None for this model None for this model
MIT4.12/9.5None for this model None for this model
MIT4.28/11.88None for this model None for this model
MIT4.28/14None for this model None for this model
MIT4.28/9.5None for this model None for this model
MIT4.75/16None for this model None for this model
MIT411.88None for this model None for this model
MIT414None for this model MIT414: DWG | DXF
MIT416None for this model None for this model
MIT418None for this model None for this model
MIT420None for this model None for this model
MIT49.5None for this model None for this model
MIT5.12/16None for this model None for this model
MIT9.5None for this model None for this model

   
top
Order free catalogs by mail
top top top
Fliers (PDFs):
top

Home | About Simpson Strong-Tie | Contact Simpson Strong-Tie | Browse Products | Product Use Information
Privacy Policy | User Agreement | Limited Warranty | Parent Company

Stay informed! Sign up for Simpson Strong-Tie newsletters

Copyright © 2012, Simpson Strong-Tie Company Inc. All Rights Reserved
Contact Webmaster with questions or comments.

Printed from
© 2012 Simpson Strong-Tie®